Rod Pump Performance
Volumetric displacement, stroke length and pump intake conditions.
Pump Displacement
PO.RP.Pump.DisplacementCalculates theoretical pump displacement, [bbl/d].PO.RP.Pump.Displacement.FromDiameterCalculates theoretical pump displacement from plunger diameter, [bbl/d].PO.RP.Pump.Disp.EffCalculates effective pump displacement accounting for fillage, [bbl/d].PO.RP.Pump.FillageCalculates pump fillage from actual and theoretical production, [fraction].PO.RP.Pump.VolEffCalculates volumetric efficiency of the pump system, [fraction].
Stroke & Intake
PO.RP.Pump.Stroke.EffCalculates effective plunger stroke from surface stroke, stretch and plunger overtravel, Sp = S + e_p − (ΔLr + ΔLt) (Economides Eq. 20-9), [in].PO.RP.Pump.PsubCalculates submergence pressure from fluid column height, [psi].PO.RP.Pump.PIPCalculates pump intake pressure (PIP), [psi].PO.RP.Pump.OvertravelCalculates plunger overtravel from rod-string acceleration, e_p = 5.79e-4·S·L²·N²/E for steel rods (overtravel term of Economides Eq. 20-10), [in].PO.RP.Pump.NetLiftCalculates the net lift the pump works against, L_N = H + p_tf/(0.433·SG) (Economides Eq. 20-14), [ft].
Can't find what you need? Request a formula