PO.ESP.TDH Function


Description:

Calculates Total Dynamic Head for ESP sizing, [ft].

Excel Function Syntax:

=PO.ESP.TDH(TVD_pump, WHP, PIP, friction_head, SG)

Parameters:

Parameter Description
TVD_pump True vertical depth to pump intake, [ft].
WHP Wellhead pressure, [psi].
PIP Pump intake pressure, [psi].
friction_head Tubing friction losses as head, [ft].
SG Fluid specific gravity, [dimensionless].

Used in Blueprints

ESP System Design - TDH Calculation

Complete ESP system design calculating Total Dynamic Head (TDH) and all head components.

Missing a formula? Suggest a New Formula