Rod Pump Loads & Torque Functions
Polished rod loads, counterbalance effect and gearbox torque.
21 functions
PO.RP.Load.FluidLoad
Calculates fluid load on plunger, [lbf].
PO.RP.Load.PPRL
Calculates Peak Polished Rod Load using API RP 11L method, PPRL = Wrf + (F1/Skr)*Skr, [lbf].
PO.RP.Load.MPRL
Calculates Minimum Polished Rod Load using API RP 11L method, MPRL = Wrf - (F2/Skr)*Skr, [lbf].
PO.RP.Load.PPRL.Simple
Calculates simplified PPRL (static, no dynamic effects), [lbf].
PO.RP.Load.MPRL.Simple
Calculates simplified MPRL (static, no dynamic effects), [lbf].
PO.RP.Load.Range
Calculates polished rod load range (PPRL - MPRL), [lbf].
PO.RP.Load.Nmax
Calculates the highest pumping speed that keeps the downward acceleration at the top of the stroke within a fraction L of gravity, N = sqrt(70,471.2·L/(S·(1 ∓ c/h))) (Guo Eq. 12.34), [SPM].
PO.RP.Load.F1.Mills
Calculates the upstroke acceleration factor F1 of the approximate (Mills) polished rod load, F1 = S·N²·(1 ± c/h)/70,471.2 (Guo Eqs. 12.20 and 12.21), [dimensionless].
PO.RP.Load.F2.Mills
Calculates the downstroke acceleration factor F2 of the approximate (Mills) polished rod load, F2 = S·N²·(1 ∓ c/h)/70,471.2 (Guo Eqs. 12.23 and 12.24), [dimensionless].
PO.RP.Load.PPRL.Mills
Calculates Peak Polished Rod Load with the approximate (Mills) acceleration factor, PPRL = Wf − SG·62.4·Wr/490 + Wr·(1 + F1) (Guo Eq. 12.17), [lbf].
PO.RP.Load.MPRL.Mills
Calculates Minimum Polished Rod Load with the approximate (Mills) acceleration factor, MPRL = Wr·(1 − F2) − SG·62.4·Wr/490 (Guo Section 12.4.2), [lbf].
PO.RP.Torque.IdealCBE
Calculates ideal counterbalance effect from rod weight and fluid load, [lbf].
PO.RP.Torque.IdealCBE.Loads
Calculates ideal counterbalance effect from PPRL and MPRL, [lbf].
PO.RP.Torque.Adjustment
Calculates counterbalance adjustment needed, [lbf]. Positive = add weight.
PO.RP.Torque.Net
Calculates net gearbox torque at a given crank angle, [lbf.in].
PO.RP.Torque.Peak
Calculates estimated peak net torque (simplified), [lbf.in].
PO.RP.Torque.PRHP
Calculates polished rod horsepower from the dynamometer card work load, [hp].
PO.RP.Torque.PRHP.FromCard
Calculates polished rod horsepower from dynamometer card dimensions, PRHP = C·S·N·A2/(33,000·12·L) (Guo Section 18.4), [hp].
PO.RP.Torque.HHP
Calculates the hydraulic horsepower to lift the produced liquid, P_h = 7.36e-6·q·SG·L_N (Economides Eq. 20-13), [hp].
PO.RP.Torque.FHP
Calculates the horsepower lost to friction in the pump, polished rod and rod string, P_f = 6.31e-7·Wr·S·N (Economides Eq. 20-15), [hp].
PO.RP.Torque.PMHP
Calculates the prime mover horsepower, P_pm = Fs·(P_h + P_f) (Economides Eq. 20-12), [hp].