PO.PTA.Pw.VW

Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir, [psi].

PO.PTA.Pw.VW.LinSealF

Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with linear sealing fault boundary, [psi].

PO.PTA.Pw.VW.LinConP

Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with linear constant pressure boundary, [psi].

PO.PTA.Pw.VW.PerpSealF

Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with perpendicular sealing faults boundary, [psi].

PO.PTA.Pw.VW.PerpConP

Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with perpendicular constant pressures boundary, [psi].

PO.PTA.Pw.VW.PerpMix

Calculates wellbore pressure drop for vertical well in infinite homogeneous reservoir with perpendicular mixed boundaries (boundary 1 - fault, boundary 2 - constant pressure), [psi].

PO.PTA.Horner.Ratio

Calculates the Horner time ratio (tp + dt)/dt, the x-axis of a Horner plot, [dimensionless].

PO.PTA.Horner.k

Calculates permeability from the semilog slope of a buildup or drawdown, k = 162.6·q·B·Ul/(abs(m)·h), [mD].

PO.PTA.Horner.S

Calculates the skin factor from the semilog straight line and abs(m); for a drawdown pass Pi as P1hr and the line's 1-hour pressure as Pwf, [dimensionless].

PO.PTA.Horner.Pstar

Calculates the extrapolated pressure p* where the Horner straight line reaches a time ratio of 1, p* = Pws + abs(m)·log10((tp + dt)/dt), [psi].

Can't find what you need? Request a Formula