PO.FA.Hydrate.Teq

Calculates the hydrate formation temperature of a sweet gas with free water from its gravity (Towler-Mokhatab 2005 fit of the Katz chart; no N2, CO2, H2S or inhibitor correction). At 1,000 psia, gravity 0.8: 67.6 degF vs 66 degF on Ahmed's chart, [degF].

PO.FA.Hydrate.Peq

Calculates the hydrate formation pressure of a sweet gas with free water, the inverse of PO.FA.Hydrate.Teq (Towler-Mokhatab Katz-chart fit; no N2, CO2, H2S or inhibitor correction). At 60 degF, gravity 0.7: 721 psia vs 680 psia on Ahmed's chart, [psi].

PO.FA.Hydrate.Peq.ByOstergaard

Calculates the hydrate dissociation pressure of a hydrocarbon fluid, black oil to lean gas, by Østergaard et al. (2000), fitted over 32 to 68 degF, with no N2, CO2 or inhibitor correction, [psi].

PO.FA.Hydrate.dT

Calculates temperature depression from inhibitor using Hammerschmidt equation, [deltaF].

PO.FA.Hydrate.dT.MeOH

Calculates temperature depression from methanol using Hammerschmidt equation, [deltaF].

PO.FA.Hydrate.dT.MEG

Calculates temperature depression from MEG using Hammerschmidt equation, [deltaF].

PO.FA.Hydrate.Conc

Calculates required inhibitor concentration for target temperature depression, by weight, [%].

PO.FA.Hydrate.Conc.MeOH

Calculates required methanol concentration for target temperature depression, by weight, [%].

PO.FA.Hydrate.Conc.MEG

Calculates required MEG concentration for target temperature depression, by weight, [%].

PO.FA.Hydrate.dTsub

Calculates subcooling (hydrate formation temp minus operating temp), [deltaF].

PO.FA.Hydrate.Qinj.MeOH

Calculates methanol injection rate required, [gal/day].

PO.FA.Hydrate.Qinj.MEG

Calculates MEG injection rate required, [gal/day].

PO.FA.Corrosion.CR.CO2

Calculates CO2 corrosion rate using de Waard-Milliams correlation, [mm/yr].

PO.FA.Corrosion.Pp.CO2

Calculates CO2 partial pressure from total pressure and mole fraction, [psi].

PO.FA.Corrosion.Fug.CO2

Calculates CO2 fugacity for accurate corrosion predictions, [psi].

PO.FA.Corrosion.CR.Inh

Calculates inhibited corrosion rate, [mm/yr].

PO.FA.Corrosion.CA

Calculates required corrosion allowance, [mm].

PO.FA.Corrosion.Severity

Returns corrosion severity classification (Low/Medium/High/Severe).

PO.FA.Erosion.Ve

Calculates erosional velocity limit using API RP 14E, [ft/s].

PO.FA.Erosion.RhoMix

Calculates gas-liquid mixture density, [lb/ft3].

PO.FA.Erosion.Vmix

Calculates mixture velocity in pipe, [ft/s].

PO.FA.Erosion.Ratio

Calculates erosion ratio (V/Ve). Values >1.0 indicate erosion risk, [dimensionless].

PO.FA.Erosion.Risk

Returns erosion risk classification (Low/Medium/High/Critical).

PO.FA.Erosion.CFactor

Returns recommended C factor based on service conditions, [dimensionless].

PO.FA.Erosion.Dmin

Calculates minimum pipe diameter to avoid erosion, [in].

Can't find what you need? Request a Formula