PO.FA.Hydrate.dTsub Function
Description:
Calculates subcooling (hydrate formation temp minus operating temp), [°F].
Excel Function Syntax:
=PO.FA.Hydrate.dTsub(T_hyd, T_op)
Parameters:
| Parameter | Description |
|---|---|
| T_hyd | Hydrate formation temperature, [°F]. |
| T_op | Operating temperature, [°F]. |
Used in Blueprints
Hydrate Inhibitor Dosing
Hydrate inhibitor dosing calculations using the Hammerschmidt equation. Compares methanol and MEG for temperature depression and calculates required injection rates.
Integrated Flow Assurance Assessment
Integrated flow assurance assessment combining hydrate, corrosion, and erosion risk evaluation. Provides a comprehensive view of flow assurance challenges for production systems.