Schilthuis Aquifer Functions
Schilthuis steady-state influx proportional to pressure drawdown.
2 functions
PO.MBE.Aq.Sch.Rate
Calculates instantaneous water influx rate (Schilthuis), [bbl/d]. qw = C * (pi - p).
PO.MBE.Aq.Sch.We
Calculates cumulative water influx (Schilthuis) at every time step by trapezoidal integration, [bbl]. Spills one value per time, down a column: We(t_k) = C × ∫(pi − p)dt from the first time to t_k, so the first value is 0 and the last is the total influx.