PO.PTA.Horner.k
Description
Calculates permeability from the semilog slope of a buildup or drawdown, k = 162.6·q·B·Ul/(abs(m)·h), [mD].
Syntax
=PO.PTA.Horner.k(m, q, B, Ul, h)Parameters
| Parameter | Description |
|---|---|
| m | Semilog slope per log cycle, either sign (its magnitude is used, since a Horner plot's LINEST slope is negative), [psi]. |
| q | Flow rate before shut-in (the flowing rate for a drawdown), [bbl/d]. |
| B | Formation volume factor, [bbl/STB]. |
| Ul | Viscosity, [cP]. |
| h | Net formation thickness, [ft]. |