PO.PTA.Horner.k


Description

Calculates permeability from the semilog slope of a buildup or drawdown, k = 162.6·q·B·Ul/(abs(m)·h), [mD].

Syntax

=PO.PTA.Horner.k(m, q, B, Ul, h)

Parameters

Parameter Description
m Semilog slope per log cycle, either sign (its magnitude is used, since a Horner plot's LINEST slope is negative), [psi].
q Flow rate before shut-in (the flowing rate for a drawdown), [bbl/d].
B Formation volume factor, [bbl/STB].
Ul Viscosity, [cP].
h Net formation thickness, [ft].

Missing a formula? Suggest a New Formula