PO.RP.Load.F1.Mills


Description

Calculates the upstroke acceleration factor F1 of the approximate (Mills) polished rod load, F1 = S·N²·(1 ± c/h)/70,471.2 (Guo Eqs. 12.20 and 12.21), [dimensionless].

Syntax

=PO.RP.Load.F1.Mills(S, N, c_h, [geometry])

Parameters

Parameter Description
S Surface stroke length, [in].
N Pumping speed, [SPM].
c_h Crank-to-pitman ratio c/h, 0 to 1, [dimensionless].
geometry Optional. Pumping unit geometry: "conventional" or "air-balanced". Omitted: conventional.