PO.RP.Load.Nmax
Description
Calculates the highest pumping speed that keeps the downward acceleration at the top of the stroke within a fraction L of gravity, N = sqrt(70,471.2·L/(S·(1 ∓ c/h))) (Guo Eq. 12.34), [SPM].
Syntax
=PO.RP.Load.Nmax(S, c_h, L_acc, [geometry])Parameters
| Parameter | Description |
|---|---|
| S | Surface stroke length, [in]. |
| c_h | Crank-to-pitman ratio c/h, 0 to 1, [dimensionless]. |
| L_acc | Largest allowed downward acceleration as a fraction of gravity, about 0.5, [dimensionless]. |
| geometry | Optional. Pumping unit geometry: "conventional" or "air-balanced". Omitted: conventional. |