PO.FA.Erosion.Dmin.SI


Description

Calculates minimum pipe diameter to avoid erosion, [cm] (SI units).

Formula

=LAMBDA(Q, Ve, LET( Q_ft3s, PO.UnitConverter(Q, "m3/s", "ft3/s"), Ve_fts, PO.UnitConverter(Ve, "m/s", "ft/s"), result_in, PO.FA.Erosion.Dmin(Q_ft3s, Ve_fts), PO.UnitConverter(result_in, "in", "cm")))

Parameters

Parameter Unit Description
Q m3/s Total volumetric rate (gas + liquid) at flowing conditions, [m3/s]
Ve m/s Maximum allowable velocity (erosional velocity), [m/s]

Examples

Invocation Expected
=PO.FA.Erosion.Dmin.SI(0.159, 6.096) 18.223473

Need a custom LAMBDA? Suggest a New Lambda