PO.FA.Corrosion.Fug.CO2.SI


Description

Calculates CO2 fugacity for accurate corrosion predictions, [kPa] (SI units).

Formula

=LAMBDA(par_pCO2, T, LET( pCO2_psi, PO.UnitConverter(par_pCO2, "kPa", "psi"), T_degF, PO.UnitConverter(T, "degC", "degF"), result_psi, PO.FA.Corrosion.Fug.CO2(pCO2_psi, T_degF), PO.UnitConverter(result_psi, "psi", "kPa")))

Parameters

Parameter Unit Description
pCO2 kPa CO2 partial pressure, [kPa]
T degC Temperature, [degC]

Examples

Invocation Expected
=PO.FA.Corrosion.Fug.CO2.SI(689.5, 93.33) 689.2236

Need a custom LAMBDA? Suggest a New Lambda