PO.FA.Corrosion.CR.CO2.SI


Description

Calculates CO2 corrosion rate using de Waard-Milliams correlation, [mm/yr] (SI units).

Formula

=LAMBDA(T, par_pCO2, LET( T_degF, PO.UnitConverter(T, "degC", "degF"), pCO2_psi, PO.UnitConverter(par_pCO2, "kPa", "psi"), PO.FA.Corrosion.CR.CO2(T_degF, pCO2_psi)))

Parameters

Parameter Unit Description
T degC Temperature, [degC]
pCO2 kPa CO2 partial pressure, [kPa]

Examples

Invocation Expected
=PO.FA.Corrosion.CR.CO2.SI(93.33, 689.5) 49.637014

Need a custom LAMBDA? Suggest a New Lambda