Buildup Boundary Signatures

Tells a sealing fault from a constant-pressure boundary in a buildup by its late semilog slope, and estimates the distance to a fault.

Pressure Transient Analysis 114 rows × 20 columnsMicrosoft 365

Use this blueprint

How to use this blueprint
  1. In Excel, go to the Petroleum Office ribbon tab and click Blueprint Manager
  2. Search for Buildup Boundary Signatures
  3. Click on the blueprint to preview
  4. Click Insert to place it into your worksheet. Modify the input values to match your data.

Requires the Petroleum Office add-in for Excel. Needs Microsoft 365 or Excel 2024: it uses functions Excel 2016 doesn't have (LAMBDA, LET, MAXIFS and MINIFS), which show #NAME? there.

Get Petroleum Office

Description

Does the buildup see a sealing fault or a constant-pressure boundary, and how far away is a fault? You paste the shut-in times and pressures and set the rate, cumulative production, rock and fluid and the flowing pressure at shut-in. You read off k, skin and p* from the Horner line over the IARF window, the late semilog slope over the IARF slope that tells the two boundaries apart, and a fault's distance from where the two lines cross.

Parameters:

  • Test: the rate before shut-in and the cumulative oil (HB_q, HB_Np), whose ratio is tp
  • Rock and fluid: Bo, μ, φ, ct, rw and h (HB_Bo, HB_mu, HB_phi, HB_ct, HB_rw, HB_h)
  • Flowing pressure at shut-in: HB_Pwf, the model's until a gauge's value is typed in
  • Settings: HB_L (0.2), HB_Flat (±10 %), HB_Span (half a log cycle, for the IARF window and for the late line) and how close to twice the IARF slope a fault's late slope must be (HB_RTol, ±20 %)
  • Synthetic model: k, skin, pi, C and the distance to the boundary (HB_ModelK, HB_ModelS, HB_Pi, HB_C, HB_Lb), and which model the data comes from (HB_Case: 0 infinite-acting, 1 sealing fault, 2 constant pressure)
  • Shut-in data: Δt and pws, the region HB_Data

How to use it: Paste the shut-in times and pressures over the Δt and pws columns, type the gauge's flowing pressure at shut-in over the model's, and set q and Np. Keep the table's rows, or trim its formulas to your row count. The three signature columns stay as the reference curves for your well's k, skin and storage; set the model's k and skin to the interpreted values to compare. Three log-log plots draw the data, the fault against the infinite-acting case, and the constant-pressure boundary against it, all on the same well.

Method: A sealing fault doubles the semilog slope, so the Bourdet derivative steps up to twice its IARF level. A constant-pressure boundary, such as a gas cap or a strong aquifer, makes the pressure stop rising, so the derivative rolls over towards zero.

  • Models. The data comes from the infinite-acting vertical-well model, the same with a linear sealing fault at L, or with a linear constant-pressure boundary at L, each for a rate q from 0 to tp and then shut in.
  • IARF line. The sheet uses single-rate Horner on Horner's pseudo-producing time tp = Np/q. The Horner ratio, te = tp/ratio, Δp and the Bourdet derivative dΔp/d ln te, the IARF window and the IARF line are computed as the Horner Buildup Analysis sheet computes them: the window is the first run after the storage hump whose derivative is flat within ±10 % over at least half a log cycle, and the line is fitted over it only, for k, skin and p*. Each signature's derivative is taken on the same te.
  • Late line. The late line is the least-squares fit over the last half log cycle of the data. Its slope over the IARF slope is the boundary's signature: near 2 for a single sealing fault (the image well adds its own semilog line), below 1 for a constant-pressure boundary (the image well cancels the drawdown).
  • Fault distance. For a fault, the two lines cross at a log ratio xx, so at te = tp/10^xx, and the distance is L = √(0.000148·k·te/(φμct)), the time the image well's line-source term reaches zero.
  • Boundary check. It reads the ratio: within ±20 % of 2 is a fault, below 1 − 10 % is a roll-over, anything else is neither.

Example: The defaults are the well and reservoir the three buildup sheets share: 250 STB/d, Bo 1.25 bbl/STB, μ 1 cp, φ 20 %, ct 1.5 × 10⁻⁵ 1/psi, rw 0.354 ft, h 30 ft, k 50 mD, S 5, pi 5,000 psi and C 0.001 bbl/psi. A fault 200 ft away needs a longer test to show its doubling than the Horner sheet's, so here Np = 2.5 MSTB (tp = 240 hr) and the shut-in lasts 240 hr. The model's pwf is 4,566.29 psi. The window runs from Δt 0.42 to 4.2 hr, one log cycle and 9 points, before the fault is felt. The line gives m = 35.56 psi/cycle, k = 47.64 mD, S = 4.49 and p* = 4,962.91 psi. That p* is the early line's, below pi: with a fault, the late line extrapolates nearer pi. The last half cycle's slope is 65.01 psi/cycle, 1.83 times the IARF slope, a sealing fault. The lines cross at te = 13.8 hr, which puts the fault 180 ft away, 9.9 % short of the model's 200 ft. With the model case set to 2 the data is the constant-pressure boundary's and the ratio falls to 0.08, a roll-over; with 0 it is the infinite-acting case's, 0.99, neither.

Functions used

Names it defines (57)
NameRefers toComment
PO.PTA.Design.Rinv =LAMBDA(k, t, phi, mu, ct, SQRT(k*t/(948*phi*mu*ct))) Radius of investigation of radial flow after t hours: sqrt(k·t / (948·φ·μ·ct)), [ft].
_PO.PTA.EndWBS =LAMBDA(C,mu,k,h,S, (200000+12000*S)*C*mu/(k*h)) End of wellbore storage time, h
_PO.PTA.FaultDistance =LAMBDA(k,t,phi,mu,ct, SQRT(0.000148*k*t/(phi*mu*ct))) Distance to a sealing fault from the time the two semilog lines cross, ft
HB_q $B$4 Rate before shut-in, q, STB/d
HB_Np $B$5 Cumulative oil produced, Np, MSTB
HB_Bo $B$6 Oil formation volume factor, Bo, bbl/STB
HB_mu $B$7 Oil viscosity, μ, cp
HB_phi $B$8 Porosity, φ, %
HB_ct $B$9 Total compressibility, ct, 1/psi
HB_rw $B$10 Wellbore radius, rw, ft
HB_h $B$11 Net pay, h, ft
HB_Pwf $B$12 Flowing pressure at shut-in, pwf, psi
HB_L $B$14 Bourdet smoothing window, L, cycles
HB_Flat $B$15 IARF: derivative flat within ±, %
HB_Span $B$16 IARF and late line: over at least, cycles
HB_RTol $B$17 Fault: late slope within ± of 2× IARF slope, %
HB_ModelK $B$19 Model permeability, mD
HB_ModelS $B$20 Model skin factor
HB_Pi $B$21 Initial reservoir pressure, pi, psi
HB_C $B$22 Wellbore storage coefficient, C, bbl/psi
HB_Lb $B$23 Distance to the boundary, ft
HB_Case $B$24 Data model: 0 infinite, 1 fault, 2 const. p
HB_Inputs $B$4:$B$24 Rate, cumulative, rock and fluid, the shut-in pressure, the window and fault settings, the synthetic model and which boundary the data comes from
HB_Data $A$66:$B$102 The shut-in data: Δt since shut-in and the shut-in pressure (the synthetic model's until you paste a gauge's)
HB_Analysis $C$66:$N$102 Per row: the model pws, the Horner ratio, te, Δp, the Bourdet derivative, and the IARF window search
HB_tp $B$27 Horner producing time, tp = Np/q, hr
HB_PwfModel $B$28 Model flowing pressure at shut-in, psi
HB_Peak $B$29 Derivative peak (the storage hump) at Δt, hr
HB_From $B$30 IARF search starts after Δt, hr
HB_Qual $B$31 Half cycles flat within the tolerance
HB_CoreT $B$32 Flattest half cycle starts at Δt, hr
HB_Level $B$33 Derivative level over it, psi
HB_WinStart $B$34 IARF window starts at Δt, hr
HB_WinEnd $B$35 IARF window ends at Δt, hr
HB_WinSpan $B$36 IARF window span, cycles
HB_WinN $B$37 Points in the window
HB_R1hr $B$38 Horner ratio at Δt = 1 hr
HB_m $B$39 Semilog slope over the window, m, psi/cycle
HB_P1hr $B$40 Line pressure at Δt = 1 hr, p1hr, psi
HB_k $B$41 Permeability, k, mD
HB_S $B$42 Skin factor, S
HB_Pstar $B$43 Extrapolated pressure, p*, psi
HB_mLate $B$44 Semilog slope over the last half cycle, psi/cycle
HB_Ratio $B$45 Late slope over the IARF slope
HB_Xx $B$46 log₁₀ Horner ratio where the two lines cross
HB_tx $B$47 te where the two lines cross, hr
HB_Dist $B$48 Distance to the fault, from the crossing, ft
HB_DistErr $B$49 Distance against the model, %
HB_Rinv $B$50 Radius of investigation at the last point, ft
HB_EndWBS $B$51 End of wellbore storage, hr
HB_kErr $B$52 k against the model, %
HB_SErr $B$53 S against the model
HB_Results $B$27:$B$56 tp, the model pwf, the IARF window and line, k, S, p*, the late line, the slope ratio, the fault distance and the checks
HB_Rates $A$60:$B$61 The model's rate steps: q from 0 to tp = Np/q, then shut in
HB_Horner $B$66:$D$102 Horner Plot: IARF Line
HB_Curve $A$66:$H$102 Log-Log Diagnostic
HB_Signatures $A$66:$S$102 Sealing Fault: Derivative Doubles

Details

Inserts114 rows × 20 columns
CategoryPressure Transient Analysis
For agents and toolsDescriptor (.md)
Tagsbuildup · boundary · sealing-fault · constant-pressure · aquifer · Horner · Bourdet · derivative-doubling · well-testing

Need a custom calculation? Request a blueprint