PO.FA.Hydrate.Qinj.MeOH.SI


Description

Calculates methanol injection rate required, [L/d] (SI units).

Formula

=LAMBDA(Qw, W, LET( Qw_bbld, PO.UnitConverter(Qw, "m3/d", "bbl/d"), result_gald, PO.FA.Hydrate.Qinj.MeOH(Qw_bbld, W), PO.UnitConverter(result_gald, "gal/d", "L/d")))

Parameters

Parameter Unit Description
Qw m3/d Water production rate, [m3/d]
W - Required methanol concentration, [wt%]

Examples

Invocation Expected
=PO.FA.Hydrate.Qinj.MeOH.SI(15.9, 30) 8625.6781

Need a custom LAMBDA? Suggest a New Lambda