PO.FA.Hydrate.Qinj.MeOH.SI
Description
Calculates methanol injection rate required, [L/d] (SI units).
Formula
=LAMBDA(Qw, W, LET(
Qw_bbld, PO.UnitConverter(Qw, "m3/d", "bbl/d"),
result_gald, PO.FA.Hydrate.Qinj.MeOH(Qw_bbld, W),
PO.UnitConverter(result_gald, "gal/d", "L/d")))Parameters
| Parameter | Unit | Description |
|---|---|---|
Qw |
m3/d | Water production rate, [m3/d] |
W |
- | Required methanol concentration, [wt%] |
Examples
| Invocation | Expected |
|---|---|
=PO.FA.Hydrate.Qinj.MeOH.SI(15.9, 30) |
8625.6781 |