PO.FA.Hydrate.Qinj.MEG.SI


Description

Calculates MEG injection rate required, [m3/d] (SI units).

Formula

=LAMBDA(Qw, W, LET( Qw_bbld, PO.UnitConverter(Qw, "m3/d", "bbl/d"), result_gald, PO.FA.Hydrate.Qinj.MEG(Qw_bbld, W), PO.UnitConverter(result_gald, "gal[US]/d", "m3/d")))

Parameters

Parameter Unit Description
Qw m3/d Water production rate, [m3/d]
W - Required MEG concentration, by weight, [%]

Examples

Invocation Expected
=PO.FA.Hydrate.Qinj.MEG.SI(15.9, 30) 6.1389961

Need a custom LAMBDA? Suggest a New Lambda