PO.SCAL.VanGenuchten.Sw.SI


Description

Van Genuchten saturation from capillary pressure, [fraction]. Inverse of Pc function (SI units).

Formula

=LAMBDA(Pc, Swi, alpha, n, LET( Pc_psi, PO.UnitConverter(Pc, "kPa", "psi"), alpha_1psi, PO.UnitConverter(alpha, "1/kPa", "1/psi"), PO.SCAL.VanGenuchten.Sw(Pc_psi, Swi, alpha_1psi, n)))

Parameters

Parameter Unit Description
Pc kPa Capillary pressure, [kPa]
Swi - Irreducible water saturation, [fraction]
alpha 1/kPa Fitting parameter, [1/kPa]
n - Pore size distribution parameter, [dimensionless]

Examples

Invocation Expected
=PO.SCAL.VanGenuchten.Sw.SI(2068, 0.2, 0.000145, 2) 0.96629055

Need a custom LAMBDA? Suggest a New Lambda