PO.MBE.Ce.UnSat.Oil.SI


Description

Calculates effective compressibility for undersaturated oil reservoir, [1/kPa] (SI units).

Formula

=LAMBDA(co, cw, cf, Swc, LET( co_1psi, PO.UnitConverter(co, "1/kPa", "1/psi"), cw_1psi, PO.UnitConverter(cw, "1/kPa", "1/psi"), cf_1psi, PO.UnitConverter(cf, "1/kPa", "1/psi"), result_1psi, PO.MBE.Ce.UnSat.Oil(co_1psi, cw_1psi, cf_1psi, Swc), PO.UnitConverter(result_1psi, "1/psi", "1/kPa")))

Parameters

Parameter Unit Description
co 1/kPa Oil compressibility, [1/kPa]
cw 1/kPa Water compressibility, [1/kPa]
cf 1/kPa Formation compressibility, [1/kPa]
Swc - Connate water saturation, [fraction]

Examples

Invocation Expected
=PO.MBE.Ce.UnSat.Oil.SI(0.0000014503, 0.000000435, 0.00000058, 0.25) 2.36863333E-06

Need a custom LAMBDA? Suggest a New Lambda