PO.MBE.Ce.Total.SI


Description

Calculates total system compressibility, [1/kPa]. ct = Sg*cg + Sw*cw + cf (SI units).

Formula

=LAMBDA(cg, cw, cf, Sg, Sw, LET( cg_1psi, PO.UnitConverter(cg, "1/kPa", "1/psi"), cw_1psi, PO.UnitConverter(cw, "1/kPa", "1/psi"), cf_1psi, PO.UnitConverter(cf, "1/kPa", "1/psi"), result_1psi, PO.MBE.Ce.Total(cg_1psi, cw_1psi, cf_1psi, Sg, Sw), PO.UnitConverter(result_1psi, "1/psi", "1/kPa")))

Parameters

Parameter Unit Description
cg 1/kPa Gas compressibility, [1/kPa]
cw 1/kPa Water compressibility, [1/kPa]
cf 1/kPa Formation compressibility, [1/kPa]
Sg - Gas saturation, [fraction]
Sw - Water saturation, [fraction]

Examples

Invocation Expected
=PO.MBE.Ce.Total.SI(0.00005802, 0.000000435, 0.00000058, 0.7, 0.3) 4.13245E-05

Need a custom LAMBDA? Suggest a New Lambda