Description

Calculates dimensionless time for VEH aquifer, [dimensionless]. tD = 0.00634*k*t / (phi*muw*ct*rr^2) (SI units).

Formula

=LAMBDA(K, t, porosity, Uw, ct, rr, LET( ct_1psi, PO.UnitConverter(ct, "1/kPa", "1/psi"), rr_ft, PO.UnitConverter(rr, "m", "ft"), PO.MBE.Aq.VEH.tD(K, t, porosity, Uw, ct_1psi, rr_ft)))

Parameters

Parameter Unit Description
K - Permeability, [mD]
t - Time, [days]
porosity - Porosity, [fraction]
Uw - Water viscosity, [cP]
ct 1/kPa Total compressibility, [1/kPa]
rr m Reservoir radius, [m]

Examples

Invocation Expected
=PO.MBE.Aq.VEH.tD.SI(50, 10, 0.2, 0.5, 0.0000145, 914.4) 0.03523139

Need a custom LAMBDA? Suggest a New Lambda