PO.FRAC.KGD.Length.Leakoff
Khristianovic-Geertsma-de Klerk (KGD) fracture half-length in the high-leakoff limit (K_u >= 1), [ft]. Outside the limit it is #VALUE!: use PO.FRAC.KGD.Length.NoLoss when leakoff is negligible; no closed form covers the range between.
Syntax
=PO.FRAC.KGD.Length.Leakoff(Q, Ul, h, G, C, t)Parameters
| Parameter | Description |
|---|---|
Q |
Injection rate (both wings), [bbl/min]. |
Ul |
Fluid viscosity, [cP]. |
h |
Fracture height, [ft]. |
G |
Shear modulus, [psi]. |
C |
Carter leakoff coefficient, [ft/sqrt(min)]. |
t |
Pumping time, [min]. |
Related functions
PO.FRAC.KGD.Length.NoLossKhristianovic-Geertsma-de Klerk (KGD) fracture half-length without fluid loss, [ft].PO.FRAC.KGD.PnetKhristianovic-Geertsma-de Klerk (KGD) net fracturing pressure, [psi].PO.FRAC.KGD.VolumeKhristianovic-Geertsma-de Klerk (KGD) fracture volume (both wings), [bbl].PO.FRAC.KGD.WavgKhristianovic-Geertsma-de Klerk (KGD) average fracture width, [in].PO.FRAC.KGD.WidthKhristianovic-Geertsma-de Klerk (KGD) fracture width at wellbore, [in].PO.FRAC.KGD.Width.GeneralKhristianovic-Geertsma-de Klerk (KGD) fracture width (generalized with Poisson's ratio), [in].