PO.MBE.Aq.Pot.We.SI
Description
Calculates instantaneous water influx for pot aquifer, [m3]. We = ct * Wi * deltaP (SI units).
Formula
=LAMBDA(ct, Wi, deltaP, LET(
ct_1psi, PO.UnitConverter(ct, "1/kPa", "1/psi"),
Wi_bbl, PO.UnitConverter(Wi, "m3", "bbl"),
deltaP_psi, PO.UnitConverter(deltaP, "kPa", "psi"),
result_bbl, PO.MBE.Aq.Pot.We(ct_1psi, Wi_bbl, deltaP_psi),
PO.UnitConverter(result_bbl, "bbl", "m3")))Parameters
| Parameter | Unit | Description |
|---|---|---|
ct |
1/kPa | Total compressibility, [1/kPa] |
Wi |
m3 | Initial aquifer volume, [m3] |
deltaP |
kPa | Pressure drop = pi - p, [kPa] |
Examples
| Invocation | Expected |
|---|---|
=PO.MBE.Aq.Pot.We.SI(0.0000145, 15900, 17237) |
3973.9904 |