PO.IPR.VW.PSS.Rate.ByKlins.SI


Description

Calculates Klins-Clark modified Vogel IPR flow rate for oil, [m3/d]. Klins & Clark (1993) correlation (SI units).

Formula

=LAMBDA(QoMax, Pres, Pb, Pwf, LET( QoMax_STBd, PO.UnitConverter(QoMax, "m3/d", "STB/d"), Pres_psi, PO.UnitConverter(Pres, "kPa", "psi"), Pb_psi, PO.UnitConverter(Pb, "kPa", "psi"), Pwf_psi, PO.UnitConverter(Pwf, "kPa", "psi"), result_STBd, PO.IPR.VW.PSS.Rate.ByKlins(QoMax_STBd, Pres_psi, Pb_psi, Pwf_psi), PO.UnitConverter(result_STBd, "STB/d", "m3/d")))

Parameters

Parameter Unit Description
QoMax m3/d Maximum oil flow rate (AOF), [m3/d]
Pres kPa Average reservoir pressure, [kPa]
Pb kPa Bubble point pressure, [kPa]
Pwf kPa Bottom-hole flowing pressure, [kPa]

Examples

Invocation Expected
=PO.IPR.VW.PSS.Rate.ByKlins.SI(318, 17237, 13790, 13790) 147.4158

Need a custom LAMBDA? Suggest a New Lambda