PO.IPR.VW.PSS.Rate.ByKlins.SI
Description
Calculates Klins-Clark modified Vogel IPR flow rate for oil, [m3/d]. Klins & Clark (1993) correlation (SI units).
Formula
=LAMBDA(QoMax, Pres, Pb, Pwf, LET(
QoMax_STBd, PO.UnitConverter(QoMax, "m3/d", "STB/d"),
Pres_psi, PO.UnitConverter(Pres, "kPa", "psi"),
Pb_psi, PO.UnitConverter(Pb, "kPa", "psi"),
Pwf_psi, PO.UnitConverter(Pwf, "kPa", "psi"),
result_STBd, PO.IPR.VW.PSS.Rate.ByKlins(QoMax_STBd, Pres_psi, Pb_psi, Pwf_psi),
PO.UnitConverter(result_STBd, "STB/d", "m3/d")))Parameters
| Parameter | Unit | Description |
|---|---|---|
QoMax |
m3/d | Maximum oil flow rate (AOF), [m3/d] |
Pres |
kPa | Average reservoir pressure, [kPa] |
Pb |
kPa | Bubble point pressure, [kPa] |
Pwf |
kPa | Bottom-hole flowing pressure, [kPa] |
Examples
| Invocation | Expected |
|---|---|
=PO.IPR.VW.PSS.Rate.ByKlins.SI(318, 17237, 13790, 13790) |
147.4158 |