PO.IPR.GW.PSS.Time.SI


Description

Calculates time to reach pseudosteady state (stabilized flow boundary) in gas well, [h] (SI units).

Formula

=LAMBDA(Re, Rw, K, porosity, Ct, Ug, LET( Re_ft, PO.UnitConverter(Re, "m", "ft"), Rw_ft, PO.UnitConverter(Rw, "m", "ft"), Ct_1psi, PO.UnitConverter(Ct, "1/kPa", "1/psi"), PO.IPR.GW.PSS.Time(Re_ft, Rw_ft, K, porosity, Ct_1psi, Ug)))

Parameters

Parameter Unit Description
Re m Drainage radius, [m]
Rw m Wellbore radius, [m]
K - Permeability, [mD]
porosity - Porosity, [fraction]
Ct 1/kPa Total compressibility, [1/kPa]
Ug - Gas viscosity, [cP]

Examples

Invocation Expected
=PO.IPR.GW.PSS.Time.SI(304.8, 0.0762, 50, 0.2, 0.0000145, 0.015) 2.249758

Need a custom LAMBDA? Suggest a New Lambda