PO.IPR.HW.SS.PI.ByJoshi.SI


Description

Calculates steady state productivity index for horizontal well using Joshi method (anisotropic reservoir), [m3/(d.kPa)] (SI units).

Formula

=LAMBDA(L, Rw, Re, h, Kz, Kxy, Bl, Ul, LET( L_ft, PO.UnitConverter(L, "m", "ft"), Rw_ft, PO.UnitConverter(Rw, "m", "ft"), Re_ft, PO.UnitConverter(Re, "m", "ft"), h_ft, PO.UnitConverter(h, "m", "ft"), result_STBdpsi, PO.IPR.HW.SS.PI.ByJoshi(L_ft, Rw_ft, Re_ft, h_ft, Kz, Kxy, Bl, Ul), result_STBdpsi * PO.UnitConverter(1, "bbl/d", "m3/d") / PO.UnitConverter(1, "psi", "kPa")))

Parameters

Parameter Unit Description
L m Length of the horizontal part of the well, [m]
Rw m Wellbore radius, [m]
Re m Drainage radius of the horizontal well, [m]
h m Reservoir thickness, [m]
Kz - Vertical permeability, [mD]
Kxy - Horizontal permeability, [mD]
Bl - Liquid formation volume factor, [m3/sm3]
Ul - Liquid viscosity, [cP]

Examples

Invocation Expected
=PO.IPR.HW.SS.PI.ByJoshi.SI(304.8, 0.0762, 304.8, 30.48, 5, 50, 1.2, 2) 0.05086665

Need a custom LAMBDA? Suggest a New Lambda