PO.FRAC.Radial.Radius.Leakoff.SI


Description

Radial (Penny-shaped) fracture radius with Carter leakoff, [m] (SI units).

Formula

=LAMBDA(Q, C, t, LET( Q_bblmin, PO.UnitConverter(Q, "m3/min", "bbl/min"), C_ft, PO.UnitConverter(C, "m", "ft"), result_ft, PO.FRAC.Radial.Radius.Leakoff(Q_bblmin, C_ft, t), PO.UnitConverter(result_ft, "ft", "m")))

Parameters

Parameter Unit Description
Q m3/min Injection rate, [m3/min]
C m/sqrt(min) Carter leakoff coefficient, [m/sqrt(min)]
t - Pumping time, [min]

Examples

Invocation Expected
=PO.FRAC.Radial.Radius.Leakoff.SI(0.159, 0.001, 10) 3.012242

Need a custom LAMBDA? Suggest a New Lambda