PO.FRAC.Leakoff.Eff.SI
Description
Fracturing fluid efficiency, [fraction] (SI units).
Formula
=LAMBDA(Vfrac, Vtotal, LET(
Vfrac_bbl, PO.UnitConverter(Vfrac, "m3", "bbl"),
Vtotal_bbl, PO.UnitConverter(Vtotal, "m3", "bbl"),
PO.FRAC.Leakoff.Eff(Vfrac_bbl, Vtotal_bbl)))Parameters
| Parameter | Unit | Description |
|---|---|---|
Vfrac |
m3 | Fracture volume, [m3] |
Vtotal |
m3 | Total fluid pumped, [m3] |
Examples
| Invocation | Expected |
|---|---|
=PO.FRAC.Leakoff.Eff.SI(0.159, 1.59) |
0.1 |