PO.FRAC.Leakoff.Cv.SI


Description

Viscosity-controlled leakoff coefficient (Cv), [m/sqrt(min)] (SI units).

Formula

=LAMBDA(K, porosity, ct, dP, Ufrac, LET( ct_1psi, PO.UnitConverter(ct, "1/kPa", "1/psi"), dP_psi, PO.UnitConverter(dP, "kPa", "psi"), result_ft, PO.FRAC.Leakoff.Cv(K, porosity, ct_1psi, dP_psi, Ufrac), PO.UnitConverter(result_ft, "ft", "m")))

Parameters

Parameter Unit Description
K - Formation permeability, [mD]
porosity - Formation porosity, [fraction]
ct 1/kPa Total compressibility, [1/kPa]
dP kPa Pressure difference (Pfrac - Pres), [kPa]
Ufrac - Fracturing fluid viscosity, [cP]

Examples

Invocation Expected
=PO.FRAC.Leakoff.Cv.SI(50, 0.2, 0.0000145, 3448, 50) 0.00142945

Need a custom LAMBDA? Suggest a New Lambda