Gas Pipeline Flow Analysis


Spreadsheet

35 rows x 3 columns

fx
A B C
1 Gas Pipeline Flow Analysis
2 Pipeline Data
3 Inlet Pressure 800 psia
4 Outlet Pressure 400 psia
5 Pipe Diameter 6 inches
6 Pipe Length 20 miles
7
8 Gas Properties
9 Gas Specific Gravity 0.65 air=1
10 Average Temperature 80 degF
11 Compressibility Factor (Z) 0.92 -
12 Gas Viscosity 0.012 cP
13
14 Pipeline Efficiency
15 E (Weymouth) 1 -
16 E (Panhandle A) 0.92 -
17 E (Panhandle B) 0.95 -
18
19 Flow Rate Calculations
20 Equation Flow Rate (Mscf/d)
21 Weymouth 444375.3841
22 Panhandle A 431698.0916
23 Panhandle B 581563.7278
24
25 Outlet Pressure at 15 MMscf/d
26 Target Flow Rate 15000 Mscf/d
27 Pout (Weymouth) 799.658102 psia
28 Pout (Panhandle A) 799.4080842 psia
29 Pout (Panhandle B) 799.7696087 psia
30
31 Flow Properties at Target Rate
32 Average Pressure 799.829051 psia
33 Gas Velocity 15.51602773 ft/s
34 Gas Density 2.827113213 lb/ft3
35 Reynolds Number 2720520.833 -

Description

Calculate gas pipeline flow rates and outlet pressures using Weymouth, Panhandle A, and Panhandle B equations.

Design Steps:

  • Define pipeline geometry and gas properties
  • Calculate flow capacity using each correlation
  • Compare outlet pressures at fixed flow rate
  • Evaluate gas velocity and Reynolds number

Equation Selection:

  • Weymouth: High-pressure large-diameter pipelines, conservative
  • Panhandle A: Medium-pressure transmission lines, Re > 5M
  • Panhandle B: High-pressure large-diameter, fully turbulent flow

Typical Efficiency Factors:

  • Weymouth: E = 1.0 (theoretical)
  • Panhandle A: E = 0.92
  • Panhandle B: E = 0.95

Reference: Ikoku, C.U. (1984). Natural Gas Production Engineering.

How to use this blueprint
  1. In Excel, go to the Petroleum Office ribbon tab and click Blueprint Manager
  2. Search for Gas Pipeline Flow Analysis
  3. Click on the blueprint to preview the spreadsheet template
  4. Click Insert to place it into your worksheet. Modify the input values to match your data.
Tags:
pipelinegasWeymouthPanhandleflow-ratepressure-drop

Need a custom calculation? Request a Blueprint

An unhandled error has occurred. Reload X