ESP Pump Sizing and Selection
Spreadsheet
29 rows x 3 columns
| A | B | C | |
|---|---|---|---|
| 1 | ESP Pump Sizing | ||
| 2 | Well Data | ||
| 3 | Flow Rate | 1500 | BPD |
| 4 | Total Dynamic Head (TDH) | 6500 | ft |
| 5 | Specific Gravity | 0.92 | - |
| 6 | |||
| 7 | Pump Catalog Data | ||
| 8 | Head per Stage | 28 | ft/stage |
| 9 | Power per Stage | 0.45 | HP/stage |
| 10 | Pump Efficiency | 0.62 | fraction |
| 11 | |||
| 12 | Hydraulic Calculations | ||
| 13 | Hydraulic HP | 65.80395264 | HP |
| 14 | Brake HP | 106.1354075 | HP |
| 15 | |||
| 16 | Stage Calculations | ||
| 17 | Stages Required (exact) | 232.1428571 | stages |
| 18 | Stages Required (rounded) | 233 | stages |
| 19 | Actual Total Head | 6524 | ft |
| 20 | Total Power Required | 104.85 | HP |
| 21 | |||
| 22 | Efficiency Check | ||
| 23 | Calculated Efficiency | 0.62 | fraction |
| 24 | Efficiency (%) | 62 | % |
| 25 | |||
| 26 | Pressure Calculations | ||
| 27 | Intake Pressure | 800 | psia |
| 28 | Discharge Pressure | 3398.30303 | psia |
| 29 | Pressure Boost | 2598.30303 | psi |
Description
Calculate ESP pump sizing requirements including hydraulic horsepower, brake horsepower, number of stages, and discharge pressure.
Design Steps:
- Calculate hydraulic horsepower from flow rate and TDH
- Determine brake horsepower based on pump efficiency
- Calculate required number of stages
- Verify discharge pressure
How to use this blueprint
- In Excel, go to the Petroleum Office ribbon tab and click Blueprint Manager
- Search for ESP Pump Sizing and Selection
- Click on the blueprint to preview the spreadsheet template
- Click Insert to place it into your worksheet. Modify the input values to match your data.