ESP Motor Selection and Sizing
Spreadsheet
36 rows x 3 columns
| A | B | C | |
|---|---|---|---|
| 1 | ESP Motor Selection | ||
| 2 | Pump Requirements | ||
| 3 | Brake Horsepower Required | 85 | HP |
| 4 | Safety Factor | 1.1 | - |
| 5 | |||
| 6 | Motor Sizing | ||
| 7 | Motor HP Required | 93.5 | HP |
| 8 | Motor Rating Selected | 100 | HP |
| 9 | |||
| 10 | Electrical Data | ||
| 11 | Motor Voltage | 1500 | V |
| 12 | Motor Efficiency | 0.85 | fraction |
| 13 | Power Factor | 0.82 | - |
| 14 | |||
| 15 | Current Calculations | ||
| 16 | Motor Current | 41.19591591 | A |
| 17 | Power (kW) | 87.76470588 | kW |
| 18 | |||
| 19 | Load Analysis | ||
| 20 | Load Factor | 0.85 | fraction |
| 21 | Load Factor (%) | 85 | % |
| 22 | Load Status | Optimal loading | - |
| 23 | |||
| 24 | Efficiency at Load | ||
| 25 | Actual Efficiency | 0.85 | fraction |
| 26 | Efficiency (%) | 85 | % |
| 27 | |||
| 28 | Thermal Analysis | ||
| 29 | Fluid Temperature | 180 | F |
| 30 | Flow Rate | 1500 | BPD |
| 31 | Motor OD | 4.56 | in |
| 32 | Temperature Rise | 209.0757897 | F |
| 33 | |||
| 34 | Voltage Options | ||
| 35 | Calculated Voltage | 1480 | V |
| 36 | Nearest Standard Voltage | 1000 | V |
Description
Select and size ESP motors based on pump requirements. Includes load factor analysis and temperature rise calculations.
Motor Sizing Guidelines:
- Load factor should be 70-100% for optimal efficiency
- Temperature rise must be within motor rating
- Safety factor typically 10% above calculated requirement
How to use this blueprint
- In Excel, go to the Petroleum Office ribbon tab and click Blueprint Manager
- Search for ESP Motor Selection and Sizing
- Click on the blueprint to preview the spreadsheet template
- Click Insert to place it into your worksheet. Modify the input values to match your data.