PO.RP.Torque.PRHP.SI
Description
Calculates polished rod horsepower, [kW] (SI units).
Formula
=LAMBDA(PPRL, MPRL, S, N, LET(
PPRL_lbf, PO.UnitConverter(PPRL, "N", "lbf"),
MPRL_lbf, PO.UnitConverter(MPRL, "N", "lbf"),
S_in, PO.UnitConverter(S, "cm", "in"),
result_hp, PO.RP.Torque.PRHP(PPRL_lbf, MPRL_lbf, S_in, N),
PO.UnitConverter(result_hp, "hp", "kW")))Parameters
| Parameter | Unit | Description |
|---|---|---|
PPRL |
N | Peak polished rod load, [N] |
MPRL |
N | Minimum polished rod load, [N] |
S |
cm | Surface stroke length, [cm] |
N |
- | Pumping speed, [SPM] |
Examples
| Invocation | Expected |
|---|---|
=PO.RP.Torque.PRHP.SI(44482, 22241, 304.8, 10) |
16.947642 |