PO.PVT.Uw.1Atm.ByMcCain.SI


Description

Calculates water viscosity at 1 atm using McCain (1990) correlation, [mPa*s] (SI units).

Formula

=LAMBDA(T_degC, salinity_pct, LET( T_degF, PO.UnitConverter(T_degC, "degC", "degF"), result_cP, PO.PVT.Uw.1Atm.ByMcCain(T_degF, salinity_pct), PO.UnitConverter(result_cP, "cP", "mPa*s")))

Parameters

Parameter Unit Description
T_degC degC Temperature
salinity_pct - Salinity (wt%)

Examples

Invocation Expected
=PO.PVT.Uw.1Atm.ByMcCain.SI(93.33, 3) 0.33546012

Need a custom LAMBDA? Suggest a New Lambda