PO.IPR.VW.TF.Rate.SI


Description

Calculates transient-state production flow rate, [m3/d] (SI units).

Formula

=LAMBDA(J, Pi, Pwf, LET( J_field, J * PO.UnitConverter(1, "psi", "kPa") / PO.UnitConverter(1, "bbl/d", "m3/d"), Pi_psi, PO.UnitConverter(Pi, "kPa", "psi"), Pwf_psi, PO.UnitConverter(Pwf, "kPa", "psi"), result_bbld, PO.IPR.VW.TF.Rate(J_field, Pi_psi, Pwf_psi), PO.UnitConverter(result_bbld, "bbl/d", "m3/d")))

Parameters

Parameter Unit Description
J m3/d/kPa Productivity index for transient-state flow. It's time-dependant, [m3/d/kPa]
Pi kPa Initial reservoir pressure, [kPa]
Pwf kPa Bottom-hole flowing pressure, [kPa]

Examples

Invocation Expected
=PO.IPR.VW.TF.Rate.SI(1, 24132, 13790) 10342

Need a custom LAMBDA? Suggest a New Lambda