PO.IPR.VW.TF.Rate.SI
Description
Calculates transient-state production flow rate, [m3/d] (SI units).
Formula
=LAMBDA(J, Pi, Pwf, LET(
J_field, J * PO.UnitConverter(1, "psi", "kPa") / PO.UnitConverter(1, "bbl/d", "m3/d"),
Pi_psi, PO.UnitConverter(Pi, "kPa", "psi"),
Pwf_psi, PO.UnitConverter(Pwf, "kPa", "psi"),
result_bbld, PO.IPR.VW.TF.Rate(J_field, Pi_psi, Pwf_psi),
PO.UnitConverter(result_bbld, "bbl/d", "m3/d")))Parameters
| Parameter | Unit | Description |
|---|---|---|
J |
m3/d/kPa | Productivity index for transient-state flow. It's time-dependant, [m3/d/kPa] |
Pi |
kPa | Initial reservoir pressure, [kPa] |
Pwf |
kPa | Bottom-hole flowing pressure, [kPa] |
Examples
| Invocation | Expected |
|---|---|
=PO.IPR.VW.TF.Rate.SI(1, 24132, 13790) |
10342 |