PO.IPR.VW.TF.PI.SI


Description

Calculates transient state productivity index for vertical well, [m3/(d.kPa)] (SI units).

Formula

=LAMBDA(time, K, h, Bl, Ul, porosity, Ct, Rw, S, LET( h_ft, PO.UnitConverter(h, "m", "ft"), Ct_psi, PO.UnitConverter(Ct, "1/kPa", "1/psi"), Rw_ft, PO.UnitConverter(Rw, "m", "ft"), result_STBdpsi, PO.IPR.VW.TF.PI(time, K, h_ft, Bl, Ul, porosity, Ct_psi, Rw_ft, S), result_STBdpsi * PO.UnitConverter(1, "bbl/d", "m3/d") / PO.UnitConverter(1, "psi", "kPa")))

Parameters

Parameter Unit Description
time - Time, [h]
K - Permeability, [mD]
h m Reservoir thickness, [m]
Bl - Liquid formation volume factor, [m3/sm3]
Ul - Liquid viscosity, [cP]
porosity - Porosity, [fraction]
Ct 1/kPa Total compressibility, [1/kPa]
Rw m Wellbore radius, [m]
S - Skin factor, [dimensionless]

Examples

Invocation Expected
=PO.IPR.VW.TF.PI.SI(24, 50, 30.48, 1.2, 2, 0.2, 0.0000145, 0.0762, 0) 0.05419725

Need a custom LAMBDA? Suggest a New Lambda