PO.IPR.VW.PSS.Rate.ByVogel.SI


Description

Calculates Vogel inflow performance for pseudosteady state flow, [m3/d] (SI units).

Formula

=LAMBDA(J, P_average, Pwf, Pb, LET( J_field, J * PO.UnitConverter(1, "psi", "kPa") / PO.UnitConverter(1, "bbl/d", "m3/d"), P_average_psi, PO.UnitConverter(P_average, "kPa", "psi"), Pwf_psi, PO.UnitConverter(Pwf, "kPa", "psi"), Pb_psi, PO.UnitConverter(Pb, "kPa", "psi"), result_bbld, PO.IPR.VW.PSS.Rate.ByVogel(J_field, P_average_psi, Pwf_psi, Pb_psi), PO.UnitConverter(result_bbld, "bbl/d", "m3/d")))

Parameters

Parameter Unit Description
J m3/d/kPa Pseudosteady state productivity index of the well, [m3/d/kPa]
P_average kPa Average reservoir pressure, [kPa]
Pwf kPa Bottom-hole flowing pressure, [kPa]
Pb kPa Bubble point pressure, [kPa]

Examples

Invocation Expected
=PO.IPR.VW.PSS.Rate.ByVogel.SI(1, 17237, 13790, 13790) 3447

Need a custom LAMBDA? Suggest a New Lambda