PO.VFP.BeggsBrill.Pout


Description

Calculates outlet pipe pressure using Beggs and Brill (1973), [psi]. For any wellbore inclination. Gas properties (ρg, μg, Bg) use DAK (Z-factor) and LGE (viscosity).

Syntax

=PO.VFP.BeggsBrill.Pout(Ql, Qg, P_in, T_degF, Rho_l, Ul, SG_gas, IFT_gl, pipe_ID, pipe_length, pipe_roughness, pipe_angle)

Parameters

Parameter Description
Ql Liquid rate, [bbl/d].
Qg Gas rate, [mmscf/d].
P_in Inlet pipe pressure, [psi].
T_degF Temperature at middle point of the pipe, [degF].
Rho_l Liquid density, [lb/ft3].
Ul Liquid viscosity, [cP].
SG_gas Gas specific gravity, {1}.
IFT_gl Liquid-gas interfacial (surface) tension, [dyne/cm].
pipe_ID Pipe inner diameter, [in].
pipe_length Pipe length, [ft].
pipe_roughness Pipe relative roughness, {1}.
pipe_angle Pipe angle from horizontal, [dega]. Horizontal flow: angle = 0; Vertical well producer: angle = 90; Vertical well injector: angle = -90.

Missing a formula? Suggest a New Formula