PO.SF.PL.Liq.Pin Function
Description:
Required inlet pressure for liquid pipeline, [psia]
Excel Function Syntax:
=PO.SF.PL.Liq.Pin(P_out, Ql, Rho_l, Ul, pipe_ID, pipe_length, pipe_roughness, dH)
Parameters:
| Parameter | Description |
|---|---|
| P_out | Desired outlet pressure, [psia] |
| Ql | Liquid flow rate, [bbl/d] |
| Rho_l | Liquid density, [lb/ft3] |
| Ul | Liquid viscosity, [cP] |
| pipe_ID | Pipe inner diameter, [in] |
| pipe_length | Pipe length, [ft] |
| pipe_roughness | Relative roughness (e/D) |
| dH | Elevation change (outlet-inlet), [ft] |
Used in Blueprints
Liquid Pipeline Sizing
Design a liquid pipeline using Darcy-Weisbach pressure drop calculations. Determine required pressures, flow capacity, and verify velocity limits.