PO.GL.Valve.TRO Function
Description:
Calculates test rack opening pressure at 60°F, [psi].
Excel Function Syntax:
=PO.GL.Valve.TRO(Pd, Td, R)
Parameters:
| Parameter | Description |
|---|---|
| Pd | Dome pressure at valve depth, [psi]. |
| Td | Temperature at valve depth, [°F]. |
| R | Port to bellows area ratio (Ap/Ab), [dimensionless]. |
Used in Blueprints
Gas Lift Valve Setting
Gas lift valve setting calculations. Determines dome pressure at depth, test rack opening pressure (Ptro), closing pressure, and valve spread for IPO (injection pressure operated) valves.