PO.GL.Valve.Pdome Function


Description:

Calculates dome pressure at depth from surface dome pressure, [psi].

Excel Function Syntax:

=PO.GL.Valve.Pdome(Pd_s, Ts, Td)

Parameters:

Parameter Description
Pd_s Dome pressure at surface conditions, [psi].
Ts Surface temperature, [°F].
Td Temperature at valve depth, [°F].

Used in Blueprints

Gas Lift Valve Setting

Gas lift valve setting calculations. Determines dome pressure at depth, test rack opening pressure (Ptro), closing pressure, and valve spread for IPO (injection pressure operated) valves.