PO.GL.Valve.Pdome Function
Description:
Calculates dome pressure at depth from surface dome pressure, [psi].
Excel Function Syntax:
=PO.GL.Valve.Pdome(Pd_s, Ts, Td)
Parameters:
| Parameter | Description |
|---|---|
| Pd_s | Dome pressure at surface conditions, [psi]. |
| Ts | Surface temperature, [°F]. |
| Td | Temperature at valve depth, [°F]. |
Used in Blueprints
Gas Lift Valve Setting
Gas lift valve setting calculations. Determines dome pressure at depth, test rack opening pressure (Ptro), closing pressure, and valve spread for IPO (injection pressure operated) valves.