Gas-Lift Performance Curve and Lift-Gas Allocation

Overview

A continuous gas-lift well does not have one rate: it has a rate for every lift-gas injection rate. The gas-lift performance curve (GLPC) plots that relationship, oil rate against injection rate, and it is the basis of every injection decision on a gas-lifted field:

  • How much gas a single well should get when gas is plentiful
  • How much it should get when gas has a cost
  • How a compressor's limited delivery is shared between wells

The valve design (Valve Mechanics) decides where the gas can enter the tubing. The performance curve decides how much gas should go in once it does.


Building the Performance Curve

One Point of the Curve

Each point is a nodal-analysis solution at the point of injection. For a chosen injection rate qgiq_{gi}, the gas in the tubing above the point of injection is the formation gas plus the lift gas, expressed as a total gas-liquid ratio:

GLRt=GLRf+1000 qgiqLGLR_t = GLR_f + \frac{1000\, q_{gi}}{q_L}

Where:

  • GLRtGLR_t = total gas-liquid ratio above the point of injection (scf/STB)
  • GLRfGLR_f = formation gas-liquid ratio (scf/STB)
  • qgiq_{gi} = lift-gas injection rate (Mscf/d)
  • qLq_L = liquid rate (STB/d)

The operating point is where the inflow performance (IPR) meets the tubing performance (VLP) computed at that GLRtGLR_t. Because GLRtGLR_t itself depends on qLq_L, the crossing is solved iteratively: guess the flowing bottomhole pressure, read qLq_L from the IPR, compute the tubing intake pressure at qLq_L and GLRtGLR_t, and adjust until the two pressures agree. Repeating this at a series of injection rates traces the curve. The oil rate is qo=qL(1−fw)q_o = q_L (1 - f_w), with fwf_w the water cut.

Inverting the same balance gives the gas needed for a target total GLR:

qgi=(GLRt−GLRf) qL1000q_{gi} = \frac{(GLR_t - GLR_f)\, q_L}{1000}

Where the Gas Enters

The curve assumes the gas reaches the point of injection. The casing pressure at depth is the surface injection pressure plus the weight of the gas column:

pc(D)=pso+GgD,Gg=0.01875 γg pˉzˉ Tˉp_c(D) = p_{so} + G_g D, \qquad G_g = \frac{0.01875\, \gamma_g\, \bar{p}}{\bar{z}\, \bar{T}}

Where GgG_g is the static gas gradient (psi/ft), γg\gamma_g the lift-gas gravity, and pˉ\bar{p}, Tˉ\bar{T} (°R) and zˉ\bar{z} the column averages. The deepest point of injection is where the casing pressure exceeds the flowing tubing pressure by the design differential across the valve. More injection lightens the tubing and moves that crossing deeper, so the curve and the point of injection are found together on a pressure-depth plot (Brown 1980; Takacs 2005).


Shape of the Curve

060012001800240030004005406808209601100Lift-gas injection rate (Mscf/d)Oil rate (STB/d)Gas-Lift Performance Curve (illustrative)

The curve rises steeply, flattens, passes through a maximum and then falls. Two effects in the tubing pull against each other as gas is added:

Effect Change with more gas Effect on bottomhole pressure
Hydrostatic (gravity) term Mixture density falls Falls, so the well makes more
Friction term Mixture velocity rises Rises, so the well makes less

At low injection the gravity term dominates and each Mscf/d buys a lot of oil. At high injection friction takes over and further gas reduces the rate. A well that does not flow naturally starts at zero and needs a minimum injection before it produces at all, so its curve can rise slowly first and then steeply: that S-shape matters for allocation (see below).


Optimum Injection for One Well

Technical Optimum

With unlimited free gas, the best injection is the maximum of the curve:

dqodqgi=0\frac{dq_o}{dq_{gi}} = 0

Injecting beyond it costs gas and loses oil.

Economic Optimum

Lift gas is never free: it has to be compressed, and gas used for lift is not sold. The injection that maximises the margin Poqo−CgqgiP_o q_o - C_g q_{gi} satisfies (Kanu, Mach and Brown 1981):

dqodqgi=CgPo\frac{dq_o}{dq_{gi}} = \frac{C_g}{P_o}

Where PoP_o is the net value of a stock-tank barrel of oil and CgC_g the cost of one Mscf of lift gas, in the same currency. With oil at 60 per STB and gas at 3 per Mscf, the optimum is where one more Mscf/d of gas adds 0.05 STB/d of oil. That point lies to the left of the maximum, and on the flat top of the curve it can save a large share of the gas for a small loss of oil.


Allocating Limited Gas Between Wells

Equal-Slope Rule

When the compressor delivers less gas than the wells could use, the problem is to maximise field oil subject to the gas available GG:

max⁡∑i=1Nqo,i(qgi,i)subject to∑i=1Nqgi,i≤G\max \sum_{i=1}^{N} q_{o,i}(q_{gi,i}) \quad \text{subject to} \quad \sum_{i=1}^{N} q_{gi,i} \le G

With a Lagrange multiplier λ\lambda, every well that receives gas must operate at the same marginal oil per unit of gas:

dqo,1dqgi,1=dqo,2dqgi,2=⋯=λ\frac{dq_{o,1}}{dq_{gi,1}} = \frac{dq_{o,2}}{dq_{gi,2}} = \dots = \lambda

A well whose slope at zero injection is already below λ\lambda gets no gas. If gas were moved from a well with a low slope to one with a higher slope, the field would make more oil, so at the optimum all slopes are equal (Redden, Sherman and Blann 1974; Kanu, Mach and Brown 1981).

λ\lambda falls as more gas becomes available. When the economic limit Cg/PoC_g/P_o is reached before the gas runs out, the gas is no longer the constraint and each well goes to its own economic optimum.

Incremental Allocation

On curves known at discrete injection rates, the equal-slope split is found step by step: give each increment of gas to the well where it adds the most oil, and repeat until the gas is used. This is exact when every curve is concave (each increment adds less than the one before). On an S-shaped curve the first increments of a non-flowing well look poor even though later ones are good, and a step-by-step allocation can leave that well out wrongly; check such wells by comparing the oil from the whole block of gas they need with what it makes elsewhere.

What the Rule Leaves Out

Constraint Effect
Gathering system A common separator or flowline pressure couples the wells, so one well's gas changes the others' curves
Compressor Delivery pressure falls with rate; a lower casing pressure moves the point of injection up
Water handling A water-cut-weighted or liquid-limited facility changes the objective
Injection reach A well whose casing pressure cannot reach its design point of injection lifts from higher, on a different curve

Field network models and constrained optimisation handle these; equal slope remains the standard first answer and the check on them.


In Petroleum Office

  • PO.GL.Inj.Eff returns the total GLR from the formation GLR, injection rate and liquid rate, and PO.GL.Inj.Qgi the injection rate for a target total GLR.
  • PO.GL.Inj.Grad and PO.GL.Inj.Pd give the casing gas gradient and the injection pressure at depth.
  • The performance-curve points come from PO.IPR.VW.PSS.Rate.ByVogel for inflow and PO.VFP.HagedornBrown.Pin for the tubing.
  • The Gas-Lift Injection Pressure and Point of Injection blueprint finds the point of injection for one well, and Gas-Lift Allocation Across Four Wells by Equal Slope builds four performance curves and splits the gas by equal slope. The Gas-Lift Field Optimisation workbook combines the two.


References

  1. Kanu, E.P., Mach, J. and Brown, K.E. (1981). "Economic Approach to Oil Production and Gas Allocation in Continuous Gas Lift." Journal of Petroleum Technology, 33(10), 1887-1892.

  2. Redden, J.D., Sherman, T.A.G. and Blann, J.R. (1974). "Optimizing Gas-Lift Systems." SPE-5150-MS, SPE Annual Fall Meeting.

  3. Brown, K.E. (1980). The Technology of Artificial Lift Methods, Vol. 2a. PennWell Books.

  4. Takacs, G. (2005). Gas Lift Manual. PennWell Books.

  5. Economides, M.J., Hill, A.D., Ehlig-Economides, C., and Zhu, D. (2013). Petroleum Production Systems, 2nd Edition. Prentice Hall.

Tags: gas-lift · performance-curve · allocation · equal-slope · optimization · nodal-analysis · injection