EoS Tuning Setup


Spreadsheet

25 rows x 6 columns

fx
A B C D E F
1 EoS Tuning Setup
2 Adjustable Properties
3
4 Property Table (editable - paste values from Component.Props)
5 Component Tc (K) Pc (Pa) omega Mw (kg/mol) zi
6 methane 190.564 4599000 0.0115 0.01604 0.6
7 ethane 305.32 4872000 0.0995 0.03007 0.1
8 propane 369.83 4248000 0.1523 0.0441 0.08
9 n-butane 425.12 3796000 0.2002 0.05812 0.05
10 C7 (adjustable) 540.2 3120000 0.28 0.096 0.17
11
12 Observed Data
13 Pb observed 15000000 Pa
14 T reservoir 373.15 K
15
16 Calculated
17 Pb calculated 36826798.29 Pa
18
19 Regression
20 Error (%) 145.5119886 %
21 Error squared 4.764091235E+14
22
23 Instructions
24 1. Adjust C7 properties in B10:E10 to minimize error
25 2. Or use Excel Solver: minimize B21, changing B10:D10

Description

Framework for EoS tuning by comparing calculated vs. observed bubble point pressures. The property table uses editable cells for Tc, Pc, omega, and Mw, enabling manual adjustment or Solver-based regression.

Tuning Workflow:

  1. Build initial property table from database + SCN correlations
  2. Copy property values to editable cells (break the formula link)
  3. Compare calculated bubble point vs. observed value
  4. Adjust C7+ properties (Tc, Pc, omega) or kij to minimize error
  5. Use Excel Solver to automate regression on the error cell
How to use this blueprint
  1. In Excel, go to the Petroleum Office ribbon tab and click Blueprint Manager
  2. Search for EoS Tuning Setup
  3. Click on the blueprint to preview
  4. Click Insert to place it into your worksheet. Modify the input values to match your data.
Tags:
EoStuningregressionbubble-pointoptimization

Need a custom calculation? Request a Blueprint