PO.SF.PL.Gas.Vel.SI


Description

Gas velocity at pipeline conditions, [m/s] (SI units).

Formula

=LAMBDA(Qg, pipe_ID, P, T, Z, LET( Qg_Mscfd, PO.UnitConverter(Qg, "sm3/d", "Mscf/d"), pipe_ID_in, PO.UnitConverter(pipe_ID, "cm", "in"), P_psi, PO.UnitConverter(P, "kPa", "psi"), T_degF, PO.UnitConverter(T, "degC", "degF"), result_fts, PO.SF.PL.Gas.Vel(Qg_Mscfd, pipe_ID_in, P_psi, T_degF, Z), PO.UnitConverter(result_fts, "ft/s", "m/s")))

Parameters

Parameter Unit Description
Qg sm3/d Gas flow rate at standard conditions, [sm3/d]
pipe_ID cm Pipe inner diameter, [cm]
P kPa Pipeline pressure, [kPa]
T degC Pipeline temperature, [degC]
Z - Gas compressibility factor

Examples

Invocation Expected
=PO.SF.PL.Gas.Vel.SI(28317, 6.35, 17237, 93.33, 0.85) 0.65615912

Need a custom LAMBDA? Suggest a New Lambda