PO.SF.CH.Liq.Rate.SI
Description
Liquid flow rate through choke, [m3/d]. Uses Bernoulli equation for incompressible flow (SI units).
Formula
=LAMBDA(d_choke, dP, Rho_l, Cd, LET(
d_choke_in, PO.UnitConverter(d_choke, "cm", "in"),
dP_psi, PO.UnitConverter(dP, "kPa", "psi"),
Rho_l_lbft3, PO.UnitConverter(Rho_l, "kg/m3", "lb/ft3"),
result_bbld, PO.SF.CH.Liq.Rate(d_choke_in, dP_psi, Rho_l_lbft3, Cd),
PO.UnitConverter(result_bbld, "bbl/d", "m3/d")))Parameters
| Parameter | Unit | Description |
|---|---|---|
d_choke |
cm | Choke diameter, [cm] |
dP |
kPa | Pressure drop across choke, [kPa] |
Rho_l |
kg/m3 | Liquid density, [kg/m3] |
Cd |
- | Discharge coefficient |
Examples
| Invocation | Expected |
|---|---|
=PO.SF.CH.Liq.Rate.SI(6.35, 3448, 800, 0.85) |
21579.42 |