PO.SF.CH.Gas.Rate.Sonic.SI


Description

Gas flow rate at sonic (critical) conditions, [sm3/d]. Rate independent of downstream pressure (SI units).

Formula

=LAMBDA(P_up, d_choke, SG_gas, T, Cd, k, LET( P_up_psi, PO.UnitConverter(P_up, "kPa", "psi"), d_choke_in, PO.UnitConverter(d_choke, "cm", "in"), T_degF, PO.UnitConverter(T, "degC", "degF"), result_Mscfd, PO.SF.CH.Gas.Rate.Sonic(P_up_psi, d_choke_in, SG_gas, T_degF, Cd, k), PO.UnitConverter(result_Mscfd, "Mscf/d", "sm3/d")))

Parameters

Parameter Unit Description
P_up kPa Upstream pressure, [kPa]
d_choke cm Choke diameter, [cm]
SG_gas - Gas specific gravity (air=1)
T degC Upstream temperature, [degC]
Cd - Discharge coefficient
k - Specific heat ratio (Cp/Cv)

Examples

Invocation Expected
=PO.SF.CH.Gas.Rate.Sonic.SI(6895, 1.27, 0.65, 37.78, 0.85, 1.3) 145335.01

Need a custom LAMBDA? Suggest a New Lambda