PO.SF.CH.Gas.Pwh.SI


Description

Required upstream pressure for sonic gas flow, [kPa] (SI units).

Formula

=LAMBDA(Qg, d_choke, SG_gas, T, Cd, k, LET( Qg_Mscfd, PO.UnitConverter(Qg, "sm3/d", "Mscf/d"), d_choke_in, PO.UnitConverter(d_choke, "cm", "in"), T_degF, PO.UnitConverter(T, "degC", "degF"), result_psi, PO.SF.CH.Gas.Pwh(Qg_Mscfd, d_choke_in, SG_gas, T_degF, Cd, k), PO.UnitConverter(result_psi, "psi", "kPa")))

Parameters

Parameter Unit Description
Qg sm3/d Gas flow rate, [sm3/d]
d_choke cm Choke diameter, [cm]
SG_gas - Gas specific gravity (air=1)
T degC Upstream temperature, [degC]
Cd - Discharge coefficient
k - Specific heat ratio (Cp/Cv)

Examples

Invocation Expected
=PO.SF.CH.Gas.Pwh.SI(28317, 1.27, 0.65, 37.78, 0.85, 1.3) 1343.4183

Need a custom LAMBDA? Suggest a New Lambda