Description

Calculates test rack opening pressure at 60°F, [kPa] (SI units).

Formula

=LAMBDA(Pd, Td, R, LET( Pd_psi, PO.UnitConverter(Pd, "kPa", "psi"), Td_degF, PO.UnitConverter(Td, "degC", "degF"), result_psi, PO.GL.Valve.TRO(Pd_psi, Td_degF, R), PO.UnitConverter(result_psi, "psi", "kPa")))

Parameters

Parameter Unit Description
Pd kPa Dome pressure at valve depth, [kPa]
Td degC Temperature at valve depth, [degC]
R - Port to bellows area ratio (Ap/Ab), [dimensionless]

Examples

Invocation Expected
=PO.GL.Valve.TRO.SI(2068.5, 93.33, 0.1) 1766.6073

Need a custom LAMBDA? Suggest a New Lambda