PO.VFP.Gray.Pout Function


Description:

Calculates outlet pipe pressure using Gray (1974), [psi]. For gas wells producing liquid. Gas properties (ρg, μg, Bg) use DAK (Z-factor) and LGE (viscosity).

Excel Function Syntax:

=PO.VFP.Gray.Pout(Ql, Qg, P_in, T_degF, Rho_l, Ul, SG_gas, IFT_gl, pipe_ID, pipe_length, pipe_roughness, pipe_angle)

Parameters:

Parameter Description
Ql Liquid rate, [bbl/D].
Qg Gas rate, [mmscf/D].
P_in Inlet pipe pressure, [psi].
T_degF Temperature at middle point of the pipe, [degF].
Rho_l Liquid density, [lb/ft3].
Ul Liquid viscosity, [cP].
SG_gas Gas specific gravity, [dimensionless].
IFT_gl Liquid-gas interfacial (surface) tension, [dynes/cm].
pipe_ID Pipe inner diameter, [in].
pipe_length Pipe length, [ft].
pipe_roughness Pipe relative roughness, [dimensionless].
pipe_angle Pipe angle from horizontal, [degrees]. Horizontal flow: angle = 0; Vertical well producer: angle = 90; Vertical well injector: angle = -90.