PO.ESP.Nodal.MinPumpDepth
Description
Calculates the shallowest depth an ESP can be set and still get its required suction pressure, D − (Pwf − P_suction)/(0.433·SG) (Guo Eq. 14.2), [ft].
Syntax
=PO.ESP.Nodal.MinPumpDepth(D, Pwf, P_suction, SG)Parameters
| Parameter | Description |
|---|---|
| D | Depth of the producing interval, [ft]. |
| Pwf | Flowing bottom-hole pressure at the delivery rate, [psi]. |
| P_suction | Pressure the pump needs at its suction, on the same basis as Pwf, [psi]. |
| SG | Specific gravity of the fluid between the pump and the interval (water = 1), [dimensionless]. |