Excel Function

OutletPressureHarBrown


Description:

Calculates outlet pipe pressure for multiphase pipe flow using Hagedorn and Brown (1965) correlation, [psia]. Developed for vertical, upward flow and recommended only for near-vertical wellbores.

Excel Function Syntax:

=OutletPressureHarBrown(Ql, Rho_l, Ul, Qg, SGgas, IFTgl, pipeID, pipeLength, pipeRoughness, P_in, T)

Parameters:

ParameterDescription
QlLiquid rate, [bbl/d].
Rho_lLiquid density, [lb/ft3].
UlLiquid viscosity, [cP].
QgGas rate, [mmscf/d].
SGgasGas specific gravity, [dimensionless].
IFTglLiquid-gas interfacial (surface) tension, [dynes/cm].
pipeIDPipe inner diameter, [in].
pipeLengthPipe length, [ft].
pipeRoughnessPipe relative roughness, [dimensionless].
P_inInlet pipe pressure, [psia].
TTemperature at middle point of the pipe, [degF].

Related Theory


1 item

Related Functions


2 items

InletPressureHarBrown

Calculates inlet pipe pressure for multiphase pipe flow using Hagedorn and Brown (1965) correlation, [psia]. Developed for vertical, upward flow and recommended only for near-vertical wellbores.

PressureGradientHarBrown

Calculates pressure gradient for multiphase pipe flow using Hagedorn and Brown (1965) correlation with Griffith modification, [psi/ft]. Developed for vertical, upward flow and recommended only for near-vertical wellbores.